Assembly & Installation Instructions B115
For Direct Wire Wall-Mounted Sconces 30-4210, 30-4215 & 30-4220 Page 1 of 2
Hand-Forged, Vermont-Made Lighting and Accessories
P.O. Box 827, 154 Route 30 South, Castleton, Vermont 05735
19798 Rev A
CAUTION: FAILURE TO INSTALL THIS FIXTURE PROPERLY MAY RESULT IN SERIOUS PERSONAL
INJURY OR DEATH AND PROPERTY DAMAGE. We recommend installation by a licensed electrician.
This product must be installed in accordance with applicable installation code(s), by a person familiar with the
construction and operation of the product and the hazards involved.*
Caution: Do not exceed maximum wattage noted on fixture. Use only recommended bulbs with fixture.
To Install Fixture (Figures 1 & 2)
Component Parts
A Crossbar
B Ground Screw
C Threaded Stud (2)
D Knurl Balls (2)
E Fixture
F Caulking Lip
Caution: Be sure power is off at the main breaker box prior to installation.
1. Carefully unpack fixture from carton.
2. Using two machine screws (not provided), fasten the crossbar (A) to the
outlet box, making sure the mounting holes are level.
Note: A new outlet box comes with screws. When replacing a fixture,
retain the screws for use with the new fixture.
3. Start threaded studs (C) into appropriate holes in crossbar.
4. Move fixture (E) into position. Using suitable wire connectors (not
provided), connect the fixture wires to the supply wires; white to white,
black to black, and bare copper or green to bare copper or green. Connect
all ground wires to crossbar ground screw (B).
Caution: Make sure wire connectors are twisted on securely and
no bare wires are exposed.
(Figure 1)
5. Apply a generous bead of a suitable caulking material to caulking
lip (F) on the fixture.
6. Carefully tuck all wires behind the fixture. Place fixture (E) over
threaded studs and tighten firmly to mounting surface using knurl balls (D).
7. Restore electricity at the main breaker.
8. Install glass per instructions on next page.
(Figure 2)
(continued)
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - 19798 Rev A

Assembly & Installation Instructions B115 For Direct Wire Wall-Mounted Sconces 30-4210, 30-4215 & 30-4220 Page 1 of 2 Hand-Forged, Vermo

Seite 2

Assembly & Installation Instructions B115 For Direct Wire Wall-Mounted Sconces 30-4210, 30-4215 & 30-4220 Page 2 of 2 Hand-Forged, Vermo

Verwandte Modelle: 304215 | 304210 |

Kommentare zu diesen Handbüchern

Keine Kommentare